FlowGrid - Air-inlet grille for axial and centrifugal fans

The air-inlet grille FlowGrid: Less noise – more quality of life

FlowGrid stands for efficient noise protection features in cooling, ventilation and air-conditioning technology. ebm-papst offers a future-oriented solution for the problem of high-performance technology generating disturbing noise: FlowGrid for axial and centrifugal fans.

The grille on the air-inlet side drastically reduces the noise emissions and minimises disturbing low frequency tones.

There are often problems wherever people and technology share space. The movement of air, for example, often goes hand in hand with noise. With FlowGrid, noise-generating disturbances in the fan inflow are a thing of the past!

Less noise – Proven by measurement results with the air-inlet grille FlowGrid

With FlowGrid, ebm-papst is making a clear contribution to active noise reduction. The innovative air-intake grilles work with both axial and centrifugal fans whilst not affecting their high efficiency in any way. Using them can help to reduce or entirely avoid the use of cost-intensive, passive noise-reduction measures. It is no surprise then that FlowGrid has a patent pending. The measurement results detailed below show the benefits that FlowGrid can offer.

Applications with centrifugal fans:

Applications with axial fans:

All examples were measured under laboratory conditions. The results are dependent upon the design of the units.

Low profil air handling unit with RadiPac Ø 250

Function
Ventilation and aeration of rooms, with or without heat recovery.

Design
The spaces to be air-conditioned are supplied with conditioned air via ducts. The sound is carried through the ducts into the rooms, requiring the use of additional noise-reduction measures such as acoustic insulation.

Challenge
Noise reduction regulations must be complied with. Furthermore, the disturbing tonal noise should be prevented from entering the rooms.

Benefits of FlowGrid
Reduction of the noise level by 2.5 dB(A) and of the blade-passing noise by 9 dB. Acoustic insulation costs can be greatly reduced.

Air purifier with RadiCal Ø 310

Function
Creating a comfortable climate through purifying the air from allergens and dust particles.

Design
The fan is installed in a housing with a filter for airborne material.

Challenge
The air inflow is disturbed by the filter on the intake side and by the limited installation dimensions. As the devices are mostly installed in areas where people live or spend long periods of time, reducing noise emissions plays an important role.

Benefits of FlowGrid
Reduction of the noise level by 2.8 dB(A) and of the blade-passing noise by 10 dB. This leads to a comfortable climate without any disturbing operating noises.

Air-water heat pump with RadiCal Ø 450

Function
Heat is extracted from the outside air. This is used to heat the residential building via a circulatory system.

Design
The centrifugal fan is installed in a housing directly behind an evaporator.

Challenge
In compact heat pumps, the evaporator is placed very close to the fan. Excess noise is created by the disturbed air inflow. As they are used in residential buildings, however, noise limit values need to be complied with.

Benefits of FlowGrid
Noise limit values are complied with and the blade-passing noise is reduced by 4 dB. This results in less disturbing noise.

Central air handling unit with RadiCal Ø 630

Function
Central ventilation and aeration of rooms, with or without heat recovery and outside air treatment.

Design
Apart from the fans, components such as filters, heat exchangers, humidifiers and de-humidifiers are installed in the device. The fans press air through the device and then through ventilation ducts.

Challenge
Significant turbulences at the fan inlet, due to low distances between the fan and the walls in the intake area, as well as components of the device, impede the flow of air.

Benefits of FlowGrid
Reduction of the noise level by 3.3 dB(A) and of the blade-passing noise by 9 dB, reducing the need for acoustic insulation.

Air-water heat pump with HyBlade® Ø 630

Function
Heat is extracted from the outside air. This is used to heat the residential building via a circulatory system.

Design
The axial fan is installed directly behind an evaporator for horizontal or vertical air conduction.

Challenge
In compact heat pumps, the evaporator is placed very close to the fan. Excess noise is created by the installation position. As heat pumps are used in residential buildings, however, noise limit values need to be complied with.

Benefits of FlowGrid
Noise limit values are complied with and the blade-passing noise is reduced by 12 dB.

Condenser with HyBlade® Ø 710

Function
Extraction of heat arising in a coolant circuit.

Design
One or multiple axial fans extract outside air through a horizontally arranged heat exchanger.

Challenge
The fans are placed very close to the heat exchanger. This results in the air inflow being disturbed. If multiple fans are used in one condenser, the uneven air inflow becomes stronger.

Benefits of FlowGrid
Reduction of the noise level by 3.9 dB(A) and a huge reduction of the blade-passing noise by 16 dB. This results in much less disturbing noise.

V-shaped condenser with HyBlade® Ø 800

Function
Extraction of heat arising in a coolant circuit.

Design
One or multiple axial fans extract outside air through a heat exchanger arranged in V-form.

Challenge
Due to the size of the heat exchanger, the distances between it and the fan vary greatly. This leads to turbulences being created in the intake area.

Benefits of FlowGrid
Reduction of the noise level by 1.3 dB(A) and of the blade-passing noise by 7 dB.

Condenser with HyBlade® Ø 800 and AxiTop

Function
Extraction of heat arising in a coolant circuit.

Design
Outside air is sucked through a heat exchanger. The condenser, with a horizontally arranged exchanger, has an axial fan with an AxiTop diffuser unit installed on the pressure side.

Challenge
Despite an already low noise level, there is still a disturbing tonal noise.

Benefits of FlowGrid
Additional reduction of the noise level by 2.8 dB(A) and of the blade-passing noise by 12 dB.

Benefits of FlowGrid at a glance

  
Reduced noise range
  • Lower noise level
  • Drastically reduced tonal noise
Maintaining efficiency
  • Air performance unaffected
  • No increase in input power
Compact design
  • Low space requirements
  • Less acoustic insulation work
Quick assembly
  • Through-holes for simple mounting
  • Customer-specific mounting on request
Effective environmental protection
  • Noise reduction as an important part of environmentally-friendly operation
Robust design
  • Made from composite material
  • Available with fire protection class UL94-5VA

Noise disturbances – Cause and solution

Excess noise is the result of the inflow of air to a fan being disturbed. Asymmetrical suction conditions, such as the walls of a device being at different distances from the fan, create powerful vortices. In the narrowest areas, these combine to form so-called vortex strings. These turbulences then hit the rotating blades of the fan, generating noise – specifically a broadband noise and additional narrowband, tonal frequency components, known as propeller noise or tonal noise.

How the noise range is looking and especially how FlowGrid, the grille on the air intake side, drastically reduces the noise-generating disturbances you can read detailed in our brochure "FlowGrid".